|
Sign In to gain access to subscriptions and/or personal tools.
|
Evaluation of Prosthetic Heart Valves by Transesophageal Echocardiography: Problems, Pitfalls, and Timing of Echocardiography
Renee B. A. Van den Brink, MD
Department of Cardiology; Academic Medical Centre; Meibergdreef 9, 1105 AZ Amsterdam; The Netherlands r.b.vandenbrink{at}amc.uva.nl
Transesophageal echocardiography (TEE) is especially suitable for examination of prosthetic valves because of the proximity of the esophagus to the heart and absence of interference with lungs and ribs. This article reviews normal and abnormal morphologic characteristics of prosthetic valves such as spontaneous echocontrast, microbubbles, strands, sutures, vegetations or thrombus. Doppler echocardiographic characteristics of normal and pathologic prosthetic valve function and the management of prosthetic valve pathology is discussed. Physicians taking care of patients with prosthetic valves should be familiar with the characteristics of normal and abnormally functioning prosthetic valves.
References
- Ionescu AA, Moreno de la Santa P, et al: Mobile echoes on prosthetic valves are not reproducible. Results and clinical implications of a multicenter study. Eur Heart J 20:140-147,1999.[Abstract/Free Full Text]
- Shu MCS, Leuer LH, Armitage TL, et al: In vitro observation of mechanical heart valve cavitation. J Heart Valve Dis 3(Suppl 1):85-93,1994.
- Kort A, Kronzon I: Microbubble formation: In vitro and in vivo observation. J Clin Ultrasound 10:117-120,1982.[Web of Science][Medline]
[Order article via Infotrieve]
- Kingsbury C, Kafesjian R, Guo G, et al: Cavitation threshold with respect to dP/dt: Evaluation in 29 mm bileaflet; pyrolytic carbon heart valves. Int J Artif Organs 16:515-520,1993.[Web of Science][Medline]
[Order article via Infotrieve]
- Kaymaz C, Özkan M, Özdemir Nihal, et al: Spontaneous echocardiographic microbubbles associated with prosthetic mitral valves: Mechanistic insights from thrombolytic treatment results. J Am Soc Echocardiogr 15:323-327,2002.[CrossRef][Web of Science][Medline]
[Order article via Infotrieve]
- Girod G, Jaussi A, Rosset C, et al: Cavitation versus degassing: In vitro study of the microbubble phenomenon observed during echocardiography in patients with mechanical prosthetic cardiac valves. Echocardiography 19(7 Pt 1):531-536,2002.[CrossRef][Web of Science][Medline]
[Order article via Infotrieve]
- Rozich JD, Edwards WD, Hanna RD, et al: Mechanical prosthetic valve-associated strands: Pathologic correlates to transesophageal echocardiography. J Am Soc Echocardiogr 16:97-100,2003.[CrossRef][Web of Science][Medline]
[Order article via Infotrieve]
- Hutchinson K, Hafeez F, Woods TD, et al: Recurrent ischemic strokes in a patient with Medtronic-Hall prosthetic aortic valve and valve strands. J Am Soc Echocardiogr 11:755-757,1998.[CrossRef][Web of Science][Medline]
[Order article via Infotrieve]
- Ionescu AA, Newman GR, Butchart EG, et al: Morphologic analysis of a strand recovered from a prosthetic mitral valve: No evidence of fibrin. J Am Soc Echocardiogr 12:766-768,1999.[CrossRef][Web of Science][Medline]
[Order article via Infotrieve]
- Orsinelli DA, Pearson AC: Detection of prosthetic valve strands by transesophageal echocardiography: Clinical significance in patients with suspected cardiac source of embolism. J Am Coll Cardiol 26:1713-1718,1995.[Abstract]
- Wang Z, Grainger N, Chambers J: Doppler echocardiography in normally functioning replacement heart valves: A literature review. J Heart Valve Dis 4:591-614,1995.[Medline]
[Order article via Infotrieve]
- Van den Brink RBA, Visser CA, Basart DCG, et al: Comparison of transthoracic and trans esophageal color Doppler flow imaging in patients with mechanical prostheses in mitral valve position. Am J Cardiol 63:1471-1474,1989.[CrossRef][Web of Science][Medline]
[Order article via Infotrieve]
- Foster GP, Isselbacher EM, Rose GA, et al: Accurate localization of mitral regurgitant defects using multiplane transesophageal echocardiography. Ann Thorac Surg 65:1025-1031,1998.[Abstract/Free Full Text]
- Pibarot PH, Dumesnil JG, Cartier PC, et al: Patient-prosthesis mismatch can be predicted at the time of operation. Ann Thorac Surg 71:S265-S268,2001.[Abstract/Free Full Text]
- Blais C, Dumesnil JG, Baillot R, et al: Impact of valve prosthesis-patient mismatch on short-term mortality after aortic valve replacement. Circulation 108:983-988,2003.[Abstract/Free Full Text]
- Lin SS, Tiong IYH, Asher CR, et al: Prediction of thrombusrelated mechanical prosthetic valve dysfunction using transesophageal echocardiography Am J Card 86:1097-1101,2000.
- Barbetseas J, Nagueh SF, Pitsavos C, et al: Differentiating thrombus from pannus formation in obstructed mechanical prosthetic valves: An evaluation of clinical, transthoracic and transesophageal echocardiographic parameters. J Am Coll Cardiol 32:1410-1417,1998.[Abstract/Free Full Text]
- Montorsi P, De Bernardi F, Muratori M, et al: Role of cinefluoroscopy, transthoracic, and transesophageal echocardiography in patients with suspected prosthetic heart valve thrombosis. Am J Cardiol 85:58-64,2000.[CrossRef][Web of Science][Medline]
[Order article via Infotrieve]
- Hurrell DG, Schaff HV, Tajik AJ: Thrombolytic therapy for obstruction of mechanical prosthetic valves. Mayo Clinics Proc 71:605-613,1996.
Seminars in Cardiothoracic and Vascular Anesthesia, Vol. 10, No. 1,
89-100 (2006)
DOI: 10.1177/108925320601000116

CiteULike Complore Connotea Del.icio.us Digg Reddit Technorati Twitter What's this?
This article has been cited by other articles:

|
 |

|
 |
 
N. K.W. Leung
Formation of Strands After Valve Replacement
Journal of Diagnostic Medical Sonography,
January 1, 2009;
25(1):
54 - 57.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
M. R. Sukernik and W. R. Davidson Jr
Incidental Finding of Incompletely Ligated Left Atrial Appendage in a Patient with Systemic Hypotension
Anesth. Analg.,
March 1, 2008;
106(3):
771 - 772.
[Full Text]
[PDF]
|
 |
|
|
|