SAGE Journals Online
Advertisement
Sign In to gain access to subscriptions and/or personal tools.

 

Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Advertisement

Sign In to gain access to subscriptions and/or personal tools.
Seminars in Cardiothoracic and Vascular Anesthesia
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via Google Scholar
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by Santrach, P. J.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Santrach, P. J.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

Devices for Monitoring Heparin and Protamine in the Operating Room

Paula J. Santrach, MD

Division of Clinical Core Laboratory Services, Department of Laboratory Medicine and Pathology, Mayo Clinic College of Medicine, Rochester, Minnesota

Ongoing monitoring of heparin anticoagulation is an essential component of many cardiothoracic and vascular surgical procedures in order to prevent significant thrombotic and hemorrhagic complications. The classic test to assess high-dose (>1 unitlmL) heparin anticoagulation is the activated clotting time. Although simple to perform, the activated clotting time has many variations and can be affected by a number of nonanalytical and patient-related factors. Correlation with the heparin concentration may be poor. Alternatively, other test systems assess the individual patient's responsiveness to heparin in order to customize the heparin administration and subsequent protamine neutralization. The choice of test and system depends on the clinical application and the desired outcome. Regulatory and accreditation standards govern this type of testing; modern instrumentation can facilitate compliance with these standards. Understanding of the nature of the test and its performance under a variety of conditions is critical for proper interpretation.

Seminars in Cardiothoracic and Vascular Anesthesia, Vol. 7, No. 4, 379-385 (2003)
DOI: 10.1177/108925320300700403


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?




Advertisement